- Horizontal blowing
- Corrosion-resistant polypropylene casing
- Digital display
- Heating priority mode (filtration pump control)
- Automatic defrosting (cycle inversion)
- Anti-freeze thermostat (minimum operating temperature: -5°C
- HP & LP safety pressure switch
- Water flow switch
- Titanium water exchanger condenser
- Rotary vane compressor
- Electronic expansion valve
- Refrigerant fluid: R32
Efficiency: Air at 28°C / Water at 28°C / 80% Humidity
| Z200 M2/ Z200 MD2 | Z200 M3 / Z200 MD3 | Z200 M4 / Z200 MD4 | Z200 M5 / Z200 MD5 |
Power returned (kW) | 6,7 | 9,3 | 11,5 | 14,8 |
Consumed power (kW) | 1,2 | 1,8 | 2,3 | 3,2 |
Average COP (Coefficient Of Performance) | 5,5 | 5 | 5,1 | 4,8 |
Efficiency: Air 15°C / Water 26°C / Humidity 70% NF-certified heat pump
| Z200 M2/ Z200 MD2 | Z200 M3 / Z200 MD3 | Z200 M4 / Z200 MD4 | Z200 M5 / Z200 MD5 |
Power returned (kW) | 4,8 | 7 | 8,1 | 10,1 |
Consumed power (kW) | 1 | 1,6 | 2 | 2,5 |
Average COP (Coefficient Of Performance) | 4,8 | 4,4 | 4 | 4 |
Recommended pool volume* (m3) | < 30 | < 45 | < 60 | < 70 | ||||
Average water flow (m3/h) | 3 | 4 | 5 | |||||
Hydraulic connection | PVC half-union, Ø 40 or 50, glued | |||||||
Electric power supply | 230 V / 1 / 50 Hz | |||||||
Nominal operating power (A) | 4,5 | 6,3 | 7,9 | 11,2 | ||||
Maximum operating power (A) | 5,2 | 7,6 | 10,2 | 13,4 | ||||
Power cable size | 3 x 2.5 | |||||||
Refrigerant fluid quantity (kg) | 0,68 | 0,85 | 0,9 | 1,1 | ||||
Acoustic Power (dB(A)) in Boost / Silent mode | 66 | 67 | 69 | 72 | ||||
Acoustic pressure at 10m (dB(A)) | 38 | 39 | 41 | 44 | ||||
Weight (kg) | 40 | 45 | 50 | 53 |
*Estimated average values for private pool with isothermal cover from 15 May to 15 September.
General
3-year guarantee
ACCESSORIES INCLUDED IN THE PACK:
- Winter cover
- PVC fittings 1/2 unions Ø 40 & Ø 50
- Anti-vibrations pads
OPTIONAL ACCESSORIES:
- Cleaning kit HP
- Remote control, Z200
- Wall mounting kit, Z200